mULTIMATE 145: ER, LPR, ZRA, POL & Datalogger details

 

 

 

HOME

 

 

TEAM AND MANAGEMENT

 

 

quality management

 

 

SERVICES

 

 

PRODUCTS

 

 

SITE MAP

 

 

CONTACTS

 

 

 

 

 

All you need for corrosion monitoring

Operating principle

LPR measurement: relies on the measuremet of the electrical resistance of the corroding electrode-electrolyte interface. The polarization resistance is measured as the ratio of the applied DC potential to the flowing current and is constant over a small range (<20mV).

ER measurement: relies on the dyrect measuremet of the electrical resistance of a probe that employs a sensing element made of the same metal as the pipeline or structure monitored; the sensing element is produced with form of wire, strip or tube. The cross-sectional area of the sensing element decreases if corrosion occurs, and its electric resistance increases according to Ohm’s law.

The mULTIMATE 145 performs a convergent autorange algorithm that can found quickly the best scale of measure.

A single mULTIMATE 145 can be used to measure an unlimited number of probes installed at different locations of a system or systems: Each Probe can be distinguished by a unique TAG number  & alphanumeric 10 characters description and measures are memorised in a non-volatile memory.

The mULTIMATE 145 is simple to operate: just set TAG number push the Measure key: the instrument will give a corrosion rate reading and automatically memorises data; can collect data from Field Unit’s; can upload setting to Field Unit’s, or can up-load data to Terminal PC acting as a portable datalogger.


 

Specifications
FIVE fuctions in one instrument.

Capable of interrogating and storing data from both data loggers and to make direct measurement from ER, LPR, POL and ZRA probes, data up-load directly to computer.

LCD display: alphanumeric 16 characters /2 lines

Direct digital readout of corrosion & corrosion rates with AUTOMATIC scale selection

Direct digital readout of Pitting Index with full automated operations

Direct digital readout of Polarization Potential (mV)  & Galvanic Current (mA)

Set Mode: Auto (timed measuring with autostore) or Man (key-press measuring)

Fully programmable Cycle interval from 1 for minute to 1 for weeck in steps of 1 minuts

Software controlled, menu driven, readings of the probe upon simple operator commands

Set Point of: Year, Month, Day, Hour, Minute, TAG number (real time clock included)

Set Display out: micron or mils - micron/y or mils/y.

Set excitation current: Anodic or Cathodic

Mode mULTIMATE Terminal for Upload/Download & exchange data with other  devices

Built-in non-volatile memory (30-Year retaining) up to 3000 Reading measures

PC RS232 connectivity (Software & cable communication included)

Hardware & software compatible with Better Manufacturer’s equipment

Power supply: eight standard AA 1.2V DC rechargeable Ni/Mh batteries

Automatic shutdown feature

Battery duration: 14 hours continuous operating or 1000 measures or 200days in autostore.

Battery charger: 220V AC –50 Hz (110V AC-60 Hz) included

Size: 200x110x70 mm

Weight: 0,5 Kg

Connecting cable: 1.5 mt in coil form.

Package: shockproof polystyrene box in vinyl carrying case.

Complete with carrying case and all necessary leads.

 BACK

 