mULTIMATE CHxx LPR details

 

 

HOME

 

 

TEAM AND MANAGEMENT

 

 

quality management

 

 

SERVICES

 

 

PRODUCTS

 

 

SITE MAP

 

 

CONTACTS

 

 

 

 

 

Multiplexed LPR Field Unit Transmitter

One function for corrosion monitoring

General informations

The CHxxLPR Transmitter monitor corrosion penetration in any environment (solid, liquid or gaseous) using the electrochemical law of potential deviation.

The transmitters are connected to LPR Probes by suitable Cables and are located near the Probes themselves.

Data can be transferred to the receiver Unit or to a Computer (laptop or notebook IBM compatible) or to a mULTIMATE 141DL 14xER/LPR equipment either through a cable RS232 or via an optical, infrared, RS232 Link.

The measurement is carried out timed and memorised in a internal memory.

The rates of measures are re-programmable 0.1-1000 hours.

Data and set-up are retained automatically for a minimum period of 30 Years

 A single instrument can be set to measure one (CH01LPR) or many (CHxxLPR multiplexed) LPR probes: each Probe can be distinguished by a unique TAG number and measures are memorised in a non-volatile memory with Tag number & Date/time associated.

 

Operating principle

The CHxxLPR Transmitter reads the electrical resistance of the corroding electrode-electrolyte interface. The polarization resistance is measured as the ratio of the applied DC potential to the flowing current and is constant over a small range (<20mV) and is related to corrosion rate.


Specifications
  • Software controlled, reprogrammable of the probe readings, upon simple operator commands via a portable PC, or our mULTIMATE 141DL 145ER/LPR equipment.
  • Programmable rate of measure 0.1-1000 Hour.
  • Set Point of: Year, Month, Day, Hour, Minute, TAG number (real time clock included).
  • Built- in non-volatile memory (30-Years retaining) up to 3000 Reading measures: can remain unattended from uploading recorded measures for up 6 months at the minimum rate (1 hour) or for up 2 Years with a standard rate interval of 8-12 hours.
  • Hardware & software compatible with Better Manufacturer’s equipment
  • PC RS232 connectivity Software & cable communication included.
  • Enclosure: Galvanised shock-proof  IP 65 rated Box.
  • Set Mode: Auto (timed measuring with autostore) & full autoranging

·         Power Supply: 12 V DC

·         Typical Charge Life: 200 days @ 1 reading/hr

  • Size: 200x170x80 mm (MMCH01)
  • Weight: 2,5 Kg (excluding cables).

 BACK

 

Corrosion monitoring & Corrosion protection - C.M.TECH