L.P.R. Probe |
|
|
![]() |
|
|
Linear polarization resistance (LPR) probe consist of three electrodes (Working Electrode, Counter Electrode and
Reference Electrode) and it gives instantaneous corrosion rate not
affected by solution resistance by means of connection with an
AE-Corr-Meter.
Protruding and Tubular Electrodes are available, depending upon the monitoring condition: High pressure LPR probe assembly is composed of the probe itself, access fitting, Hollow Plug and Heavy Duty Cover with hole. Insertion and extraction are realized by means of a Retriever Tool.Although the extractable LPR probe is the standard, it is possible supply also LPR fixed probe. This kind of probe is permanently immersed in the fluid and its replacement is possible only when the plant is not working. |
Corrosion monitoring & Corrosion protection - C.M.TECH